Siemens Controller LFL 1.322 Specification

  • Pressure
  • Maximum permissible pressure: as per relevant burner requirements.
  • Function
  • Automatic burner control for oil/gas burners with or without fan in intermittent operation.
  • Size
  • Compact, DIN rail or base mounting.
 

Siemens Controller LFL 1.322 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • FOB Port
  • AHMEDABAD
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 15 Days
  • Main Domestic Market
  • All India
 

About Siemens Controller LFL 1.322

Siemens Controller LFL 1.322

Hot Product

We are prominent Siemens make Oil & Gas Burner Sequence Controller to our clients at superior range. These are available to various sizes and made as per the specifications provided by the customers. These controllers are temperature resistance and are easy to operate and install. These are available to our clients at economical prices.


We have following Thermax Boiler programmer control box in stock.

Oil Burner Controller :

  • Siemens Burner Controller LOA 24.171 110 230V
  • Siemens Burner Controller LOA 44.171 110 230V 
  • Siemens Burner Controller LAL  1.25  110 230V 
  • Siemens Burner Controller LAL  2.14  110 230V 
  • Siemens Burner Controller LAL 2.25  110 230V 
  • Siemens Burner Controller LAL 2.65  110 230V  
  • Siemens Burner Controller LAL 3.25  110 230V  
  • Siemens Burner Controller LMO 44  110 230V 
  • Siemens Burner Controller LMO 24  110 230V 

 
Gas Burner Controller :  

  • Simens burner Controller  LFL 1.322, 110 & 230V
  • Simens burner Controller  LFL 1.333, 110 & 230V 
  • Simens burner Controller  LFL 1.355, 110 & 230V
  • Simens burner Controller  LFL 1.355, 110 & 230V
  • Simens burner Controller LFL 1.635, 110 & 230V 
  • Simens burner Controller LME 21, 110 & 230V 
  • Simens burner Controller  LME 22, 110 & 230V 
  • Simens burner Controller  LMG 21, 110 & 230V 
  • Simens burner Controller  LMG 25, 110 & 230V 
  • Simens burner Controller  LGB 21, 110 & 230V  
  • Simens burner Controller LGB 22, 110 & 230V 
  • Simens burner Controller LME 11.330, 110 & 230V    


Versatile Burner Control

The Siemens LFL 1.322 controller is engineered to provide automatic management for oil and gas burners with or without a fan. Its design supports intermittent operation and is suitable for a broad range of industrial and commercial applications, ensuring consistent performance and enhanced safety.


Flexible Installation

With its compact form and the ability to be mounted on a DIN rail or base, the LFL 1.322 ensures straightforward integration into existing burner systems. Its versatility allows installation in any operating position, facilitating use in diverse setups and easing replacement or upgrade projects.

FAQs of Siemens Controller LFL 1.322:


Q: How is the Siemens Controller LFL 1.322 reset after a lockout event?

A: The controller features both manual and remote reset options, providing users the flexibility to reset the unit conveniently, depending on the installation environment and operational preferences.

Q: What type of flame detectors can be connected to the LFL 1.322?

A: This controller supports both UV flame detectors and ionisation probes, making it suitable for reliable flame supervision in a variety of burner systems.

Q: Where can the LFL 1.322 be installed within a burner system?

A: The LFL 1.322 can be installed in any operating position, thanks to its compact design and DIN rail or base mounting options, offering maximum flexibility during setup.

Q: What benefits does the visual lockout indicator provide?

A: The clear visual lockout indicator allows operators to quickly identify burner faults or shutdowns, enhancing safety while reducing troubleshooting and downtime.

Q: When should the LFL 1.322 controller be used in burner applications?

A: This controller is ideal for intermittent operation of oil or gas burners in industrial and commercial environments, particularly when compatibility with UV or ionisation flame detection is required.

Q: What process does the LFL 1.322 controller manage?

A: It governs the safe automatic start, operation, supervision, and shutdown of oil or gas burners, ensuring compliance with relevant safety and performance standards.

Q: What is the recommended pressure limitation for the LFL 1.322?

A: The maximum permissible pressure should align with the requirements specified for the burner system it is installed with, ensuring both safety and optimal performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sequence Controllers Category

Temprature controller KS 40-108-9090 M-D-35

Temprature controller KS 40-108-9090 M-D-35

Price Range 2000.00 - 5000.00 INR / Unit

Minimum Order Quantity : 1 Piece

Function : Electronic temperature control for industrial applications

Accuracy : 0.5% of measuring range

Pressure : Not applicable (Temperature controller)

Size : 48 x 96 mm (DIN 43700 standard)

Thermax Boiler Sequence Controller LFL 1.333

Thermax Boiler Sequence Controller LFL 1.333

Price Range 2000.00 - 5000.00 INR / Unit

Minimum Order Quantity : 1 Piece

Function : Boiler Sequence Controller for automatic and safe operation of gas/oil burners

Accuracy : Reliable sequence control as per safety standards

Pressure : Supports standard burner operating pressure ranges

Size : Compact, Panel Mounting Type

Honeywell Sequence Controller DLG 976

Honeywell Sequence Controller DLG 976

Price Range 2000.00 - 5000.00 INR / Unit

Minimum Order Quantity : 1 Piece

Function : Microprocessor based Sequence controller for gas and oil fired burners

Accuracy : High accuracy operation for burner sequences

Pressure : Suitable up to 500 mbar

Size : 110 x 80 x 60 mm

RIELLO RMG 88.62A2 BURNER CONTROL

RIELLO RMG 88.62A2 BURNER CONTROL

Price Range 2000.00 - 5000.00 INR / Unit

Minimum Order Quantity : 1 Piece

Function : Burner control box for supervision of gas and oil burners

Accuracy : Reliable flame detection and safety control

Pressure : Suitable for standard combustion chamber pressures

Size : Standard compact module