Honeywell Sequence Controller DLG 976 Specification

  • Switch Type
  • Automatic Sequence Switch
  • Display
  • LED Indicators
  • Output
  • Relay Output
  • Mounting Type
  • DIN Rail or Panel Mount
  • Protection Level
  • IP40
  • Phase
  • Single phase
  • Installation Type
  • Panel Mounting
  • IP Rating
  • IP40
  • Current
  • 2A
  • Product Type
  • Sequence Controller
  • Input
  • 230V AC
  • Application
  • Automatic control of gas burners and boilers
  • Supply Voltage
  • 230V AC, 10%
  • Dimension (L*W*H)
  • As per manufacturer specs
  • Weight
  • Approx. 300 g
 

Honeywell Sequence Controller DLG 976 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • FOB Port
  • AHMEDABAD
  • Payment Terms
  • Telegraphic Transfer (T/T)
  • Supply Ability
  • Piece
  • Delivery Time
  • Ex Stock Days
  • Main Export Market(s)
  • Western Europe, Australia, North America, Eastern Europe, Middle East, Central America, South America, Asia, Africa
  • Main Domestic Market
  • All India
 

About Honeywell Sequence Controller DLG 976

We are affianced in manufacturing and supplying an exceptional quality Honeywell Sequence Controller DLG 976. The offered controller is highly appreciated by our customers for its flawless quality and finds wide applications in steel, glass, iron and other industries. This controller is manufactured using quality assured components with the aid of contemporary technology at our well-developed production unit. Moreover, our customers can purchase this Honeywell Sequence Controller from us at affordable prices.

Features:

  • Hassle free operation

  • Perfect finish

  • Minimum maintenance required

  • Excellent functionality



Versatile Program Management

Benefit from the DLG 976s seven programmable sequences, allowing you to tailor its operation for a variety of gas burner and boiler setups. Its flexible design enables adaptation to diverse heating requirements, offering both standard control options and advanced automation. Clear program indication through LED displays simplifies monitoring and adjustment.


Enhanced Safety and Rapid Response

The controllers robust safety features include a flame failure response time of less than one second and both manual and automatic reset capabilities. CE certification and a flame-retardant ABS enclosure further reinforce safety, ensuring compliance with industry standards and minimizing operational risks.


Easy Installation and Robust Construction

Designed for panel mounting or DIN rail installation, the DLG 976 offers hassle-free integration into new or existing systems. The enclosure is lightweight, compact, and provides IP40 protection against dust and accidental contact, making it well-suited for industrial and commercial settings.

FAQs of Honeywell Sequence Controller DLG 976 :


Q: How is the Honeywell DLG 976 Sequence Controller typically installed?

A: The DLG 976 can be conveniently installed via DIN rail or panel mounting, ensuring compatibility with most standard control panels used for gas burners and boiler systems.

Q: What benefits does the fast flame failure response time provide?

A: With a flame failure response time of less than one second, the DLG 976 swiftly detects and responds to potential hazards, significantly improving system safety by minimizing the risk of gas leaks or uncontrolled burner operation.

Q: When should manual versus automatic reset be used with this controller?

A: The manual reset is ideal for situations requiring human intervention after a fault, ensuring thorough safety checks. Automatic reset can be used in less critical applications where uninterrupted operation is prioritized and the risk is minimal.

Q: What type of protection does the enclosure offer?

A: The DLG 976s flame retardant ABS enclosure is rated IP40, providing basic protection against solid objects and accidental contact, which helps safeguard the internal components during use.

Q: Where can the DLG 976 Sequence Controller be applied?

A: This controller is designed for automatic firing sequence management in gas burners and boilers, making it suitable for industrial, commercial, and institutional heating systems needing reliable and safe combustion control.

Q: What is the process for monitoring the devices status?

A: Status is easily monitored via built-in LED indicators, which display the operational state, program sequence, and fault conditions, assisting operators in real-time management and troubleshooting.

Q: How does the supply voltage range benefit installation?

A: With an input of 230V AC 10%, the DLG 976 tolerates common voltage fluctuations, ensuring stable performance and reducing the likelihood of operational interruptions in typical power environments.