Siemens Flame Detector Relay LFE 10 Specification

  • Function
  • Flame monitoring relay for use with Siemens flame detectors (UV or IR types)
  • Size
  • Standard DIN rail mountable housing, approximately 70 mm (W) x 100 mm (H) x 110 mm (D)
  • Operating Voltage
  • 230 V AC, 50/60 Hz
  • Power Consumption
  • Approx. 4 VA
  • Flame Detectors Supported
  • Siemens QRB, QRC, and QRA series (UV/IR types as per relay type)
  • Standards Compliance
  • Complies with Siemens burner control safety standards
  • Weight
  • Approx. 0.35 kg
  • Mounting
  • DIN rail or surface mounting
  • Output Contacts
  • 1 changeover relay contact (SPDT), rated 5A at 250 V AC
  • Response Time
  • < 1 second
 

Siemens Flame Detector Relay LFE 10 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • FOB Port
  • AHMEDABAD
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 15 Days
  • Main Domestic Market
  • All India
 

About Siemens Flame Detector Relay LFE 10

Since inception, we have been able to place ourselves as one of the foremost manufacturer and supplier of Siemens Flame Detector Relay. Our provided product is manufactured with utmost care by utilizing quality approved components and cutting edge technology in adherence with set market quality standards. Accessible in numerous specifications as per customers needs, the offered product is used in large commercial or industrial burner for indicating the absence or presence of flame. Furthermore, our esteemed customers can avail this Siemens Flame Detector Relay from us at pocket friendly prices.

Features:

  • Robust construction

  • Resistant to electrical shock

  • Excellent performance

  • Compactness

Details:

Flame safeguard  
For the supervision of oil flames with silicon photocell detectors RAR9...  - AC 220240 V LAE10 - AC 110 V LAE10-110V 
Flame safeguard  
For the supervision of gas / oil flames with flame detector QRA... or ionization probe - AC 220240 V  LFE10- AC 110 V  LFE10-110V O.



Reliable Flame Monitoring Solution

The LFE 10 offers reliable flame detection for burner and boiler applications by supporting Siemens UV and IR flame detectors. With quick response and robust output capability, it provides a dependable safety mechanism for a variety of combustion systems. Its compliance with Siemens burner control safety standards ensures operational trust in critical environments.


Flexible Installation and Operation

Engineered for both DIN rail and surface mounting, the LFE 10 is suitable for new installations or upgrades. Its standard housing size allows easy integration in control panels, while simple wiring streamlines commissioningcatering to the needs of service providers and system integrators alike.

FAQs of Siemens Flame Detector Relay LFE 10:


Q: How is the Siemens Flame Detector Relay LFE 10 installed?

A: The relay can be mounted either on a DIN rail or directly on a surface, offering flexibility for various control panel configurations and site requirements.

Q: What types of flame detectors are compatible with the LFE 10 relay?

A: The LFE 10 supports Siemens QRB, QRC, and QRA series flame detectors, including both UV and IR types, depending on the specific relay variant.

Q: When should I consider using the LFE 10 flame detector relay in my system?

A: Use the LFE 10 when reliable flame monitoring and quick response are crucial for burner safetycommon in industrial or commercial heating systems handling gas or oil combustion.

Q: Where can I use the LFE 10 in my burner management system?

A: The relay is designed for integration into burner management and combustion control panels in facilities such as factories, boiler rooms, and commercial heating plants.

Q: What is the process for wiring the output contacts of the relay?

A: The LFE 10 features a single changeover relay contact (SPDT), rated at 5A/250V AC. Wiring should follow Siemens installation guidelines, connecting load circuits securely while observing safety standards.

Q: How does the LFE 10 benefit users in terms of safety and performance?

A: With its rapid response time (< 1 second) and compliance with Siemens safety standards, the relay enhances operational safety by ensuring prompt flame detection and reducing risks associated with burner operation.

Q: What is the power consumption and physical size of the LFE 10 relay?

A: The relay consumes approximately 4 VA and comes in a compact enclosure measuring about 70 mm wide, 100 mm high, and 110 mm deep, making it suitable for most standard panel layouts.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sequence Controllers Category

water level controller NRS 1-50

water level controller NRS 1-50

Price Range 2000.00 - 5000.00 INR / Unit

Minimum Order Quantity : 1 Piece

Accuracy : Reliable switching; repeat accuracy 1 mm

Pressure : Max. 32 bar

Size : DIN 48 x 96 mm

Function : Conductive water level control and monitoring for boilers and tanks

Siemens Gas Leak Controller LDU 11.523 A17

Siemens Gas Leak Controller LDU 11.523 A17

Price Range 2000.00 - 5000.00 INR / Unit

Minimum Order Quantity : 1 Piece

Accuracy : 1% FSD

Pressure : Suitable for low to medium gas pressure systems

Size : 96 mm x 96 mm x 56 mm (Panel Mount)

Function : Gas leak detection and control

RIELLO RMG 88.62A2 BURNER CONTROL

RIELLO RMG 88.62A2 BURNER CONTROL

Price Range 2000.00 - 5000.00 INR / Unit

Minimum Order Quantity : 1 Piece

Accuracy : Reliable flame detection and safety control

Pressure : Suitable for standard combustion chamber pressures

Size : Standard compact module

Function : Burner control box for supervision of gas and oil burners

Indian Gas Burner sequence Controller

Indian Gas Burner sequence Controller

Price Range 2000.00 - 5000.00 INR / Unit

Minimum Order Quantity : 1 Piece

Accuracy : High response time for reliable gas burner operation

Size : Compact design, approx. 120mm x 80mm x 50mm

Function : Sequencing and safe ignition of Indian gas burners